Product Details:
|
Size: | Custom Size | Color: | Black,brown |
---|---|---|---|
Material: | PU,Rubber | Delivery Time: | 3-15 Days |
Payment Terms: | T/T, Western Union | Performance: | Loader Cylinder Hydraulic Oil Sealing |
Highlight: | HIEACHI 200 Hydraulic Motor Seal Kit,HIEACHI 220 Hydraulic O Rings,HIEACHI 210 Hydraulic Rod Seals |
HIEACHI 200 210 220 Hydraulic Motor Seal Kit Custom Size O Rings
HIEACHI ZAX200 210 220 Excavator Hydraulic ADJ Seal Kit Adjust Oil Seal kit Hydraulic Cylinder Seal Kits
ZAX200 Center Joint Seal kit for Hitachi Oil Seal Excavator Parts
Model No.: | ZAX200 | Material: | PU |
Part Name: | Center Joint Seal kit | hydraulic | |
Part No.: | N/A | Structure: | control |
Appliion: | Excavator | Origin: | China |
Type: | Control valve seal kit Hydraulic Pump seal kit Travel Motor seal kit Swing Motor seal kit ADJ seal kit O ring box/kit Servo valve seal kit Pilop valve seal kit Breaker seal kit |
Customized | YES |
Hydraulic Cylinder Seal Kits Appliion
1. Industrial/ heavy construction:
1) Oil seal for cylinder
2) Hydraulic pump seal kit
3) Control valve seal kit
4) Oil seal
5) Framework oil seal , Connect glue
2. For Vehicles:
1) Oil seals
2) Lip seals
3) Power steering kits
4) Shock absorber
5) Engine gasket
Recommended Periodic Insulation Tests
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Tools Needed
142-5055 Insulation Testing Gp
9U-6003 Insulation Testing Gp Periodically, use an insulation tester to check the insulation resistance of the generator's main stator winding. The frequency of this test is determined by the generator's environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every three months.
The generator set is not protected from the elements in an enclosed area. Test every three months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every twelve months (minimum)
.
Contact Person: SUNNY
Tel: 86 18605253464