Product Details:
|
Oem: | Accpetable | Packing: | Carton Box |
---|---|---|---|
Name: | Seal Kit Hydraulic Oil Seal From Seal Supplier | Material: | Pu Nbr Ptfe |
Colour: | Black | Service: | OEM Customized Services |
Highlight: | Seal Assy 1672183,2332615 Seal Assy,1672201 Seal Assy |
1672186 1672200 2332615 1672201 HBI SEAL AS BUFFER parts Seal Assy
6J9733 - Seal Assy 8C9122 1672186 fits
Replacement For 8C9125 - SEAL ASSEM 1672200 5J3616 Fits (Fits )
Amhillras Replacement For 8C9125 - SEAL ASSEM 1672200 5J3616 Fits (Fits )
BACKHOE BH150
BACKHOE LOADER 414E 416B 416C 416D 416E 416F 420D 420E 420F 422E 424D 426C 428B 428C 428D 428E 430D 430E 430F 432D 432E 434E 436C 438C 438D 442D 442E 444E
COMPACT WHEEL LOADER 902 904B 904H 906 906H 906H2 907H 907H2 908 908H 908H2
EXCAVATOR 315C 315D L 322B L 325B L 330B L
Electric Power Generation:
3412 GENSET (S/N: 4BZ1-UP)
Engine:
3406B (S/N: 4TB1-UP; 7XC1-UP; 9PL1-UP)
3406C (S/N: 2AM1-UP; 2MZ1-UP)
3408 (S/N: DLA1-UP; 67U1-UP; 99U1-UP; 78Z1-UP)
3408B (S/N: 9TD1-UP; 67U1-UP; 99U1-UP; 78Z1-UP)
3408C (S/N: TAM1-UP; 67U1-UP; 99U1-UP; 78Z1-UP)
3412 (S/N: 7HG1-UP; 5RL1-UP; BCS1-UP; 38S1-UP)
3412C (S/N: BAK1-UP; 5FL1-UP; 9EP1-UP; RLR1-UP; 8AR1-UP; 9BR1-UP; TFT1-UP; BCW1-UP; LRY1-UP)
3412E (S/N: TGC1-UP; 4CR1-UP)
G3408 (S/N: 6NB1-UP; 6RJ1-UP)
G3408C (S/N: 8YR1-UP; BAZ1-UP)
G3412 (S/N: GNA1-UP; R7A1-UP; 7DB1-UP; KAP1-UP)
Generator Rated Above 600 Volts. Do not attempt to measure line voltage or line current on generator rated 600 volts with direct reading test metering equipment. Potential and current transformers rated for applicable voltages must be used, even though test instruments have high voltage scales. DO NOT rely on test instrument insulation alone when working on power circuits above 600 volts.
Place the belt tension tool against the top of the belt at the center of the span. Apply a force at right angles to the belt. Apply enough force to deflect the belt to the point where the marker ring is level with the top of the adjacent belt.
Adjust the tension until the belt tension tool indies approximately 8.5 kgf.
To adjust the tension, adjust the locknut of the threaded adjusting rod.
Turn the nut clockwise to shorten the rod and increase belt tension. Turn the nut counterclockwise to lengthen the rod and decrease belt tension. Note: Do not over tension the belts.
Tighten the four fasteners on the idler system. Torque fasteners to 210 N m (155 lb ft).
Install pulley guards.
Run engine for 20 minutes. Recheck belt tension.
Contact Person: SUNNY
Tel: 86 18605253464